he digital camera head is an advanced micro imagery tool. It may be a viewing head with a digital camera built-in or an electron eyepiece. All common microscopes can be fitted with it. Connecting with your PC, the micro-image will be displayed on your PC, and you will be relaxed from the tired traditional micro-observation.

EtAMCAP application software for using the camera. Opticstar View application software with more advanced functions and usability. The first step is to install software that makes the SL-131C compatible with Microsoft’s Windows DirectShow model. Fist Light - Qguide (aka QHY 5) Equipment Discussions. It's just different mate, the toucam is king for planetary imaging, but it would need a long exposure mod and adpater for use with my little guidescope.and Iam pretty sure it would not match the QHY unit for sensitivity. Sep 23, 2020 AMCap is a full-fledged screen recorder, which lets you capture and preview footage from camcorder devices and webcams. Since the program is compatible with Microsoft DirectShow, it can deliver high-quality recordings. These days, you can choose from a wide range of screen recording applications. Scarica gratuitamente eMPIA All2.10.0722.0 Camera Driver per Windows XP/Vista/7/8/8.1/10 (x86;x64). By using the software “etAMCAP”, you can get high resolution video capture or still image capture which could be up to 1280.1024 pixels. Enter the options setting, choose video capture pin and then set the video compression to be YUV2. The video resolution (size) could be set from range 320.240 to 1280.1024.

Features and Specifications:

1) High Quality Color Digital Image System

Etamcap Download

2) Resolution1280(H)*1024(V)(1.30MP)

3) CMOS Chip1/2Micron MT9M001

4) USB2.0 Connection

5) Magnification of Optical System: 0.39X

6) Capturing microscope images and showing live video on PC screen

7) Saving Still Images as BMPJPG Files

8) User-friendly Sophisticated Micro-image Process Software Included for PreviewingMeasuringComparingCountingSaving and Deleting

9) PC System Required

HardwareUSB2.0 Connecting Socket

Etacap Jefe Caan

CPUIntel P4EMS Memory256M Hard Disk512M

PC Screen Resolution1024*768

Softwarewin2000(with Mend sp4)or winxp (with Mend sp2)and directx 9.0

How to use the digital camera head

Insert the driver CD into your PC

Connect the digital camera head to your PC with the USB2.0 digital line to run the guiding program of the new hardware found.

Choose the correct button according to the information of your PC---- NEXT----NEXT---- CONTINUE----FINISH

4) Find the etAMCAPon the desktop and open it.

5) Choose ET USB 2750 Camerain Devices; Choose Previewin Options

6) How to reach resolution of 1280X1024

Choose Option----Choose Video Capture Pin---- Choose YUY2in C', and Choose 1280X1024in S.

7How to make the picture more clear.

a) Choose Option----Choose Video Capture Filter;

b) Click Photo Controlto choose the zoom multiple

c) Adjust the parameters in Proc Ampas you need;

d) Open Video Image. Choose Lightas your microscope used;

Choose Flip Verticalor Flip Horizontalto change the direction of the image.

Adjust White Balanceand Exposureas you need;

P.13

8) How to record video

After the image has been displayed on the PC screen, you should choose Set Capture Filein Filefirst, and then give a name of the capture file. Put it in your desktop or other files and open. Enter the capture file size, because AVI file will take big space, so 1M~5M bytes is the best amount you can set, which also have satisfied quality.

Choose the Capture----Start Capture, then Stop Capture. In it, you can Set Frame Rate and Set Time Limit

Etham Capital

9) How to take pictures

a) Open My Computer

b) Find a logo as right and open it. Then you can take pictures or delete them.

C) How to use measuring software

1) Install the measuring software: Double-click Digiciever1.35.exein the driver CD and open it. Choose the correct button step by step according to the information showing in your PC---- NEXT----NEXT----FINISH.

During the installing process, there may be a mend program to be installed. Dont worry about it. It does no harm to your PC.

2) Restart your PC.

3) Click start-program-Yujieviewer-yujieviewer1.35,

Preview: Click it to preview. If it doesnt work, please check the camera, and then restart the software again.

Stop: Click it to stop previewing.

Video: Click it, a pop-window let you choose if you confirm to start videoing.

Stop: Click it to stop videoing.

Zoom: Click it, and the mouse point area will be zoom+. You can choose the zoom multiple by the right scroll bar.

Zip: Choose different compress mode.

Capture: Capture a photo.

Right and left arrow: You can choose the picture you have captured. Double click the small picture to open it with the application.

“×”: You can delete the picture you have captured.

4) Windows of the measuring program

P.14

Resolution: Click it to choose different resolution.

Comparing: Click it to choose four pictures in same windows to compare with each other.

Brown: Click it to choose the different pictures for comparing.

Measuring: Click it to go to the measuring window.

Tamcap Llc

Area 1: Basic functionopen or save the picture.

Open: Open a picture

Paste: If you have copied a picture in other software, you can paste it in the measuring window.

Save: save the picture. If you have some mark in picturethe change will be saved at the same time.

Save as: Save the picture as you required.

Exit: Exit from the measuring mode.

Area 2: Measure and calibration function

Manual calibration: You can input the calibration data by yourself.

Name: You will give this calibration reference a name, we advice you can give the name with camera name and objective (such as: 1.3 mega pix--10 times), because you will choose different calibration when you will measure the object in the microscope.

Resolution: Enter the original resolution of your calibration picture. When measuring, the resolution must be same as the calibration reference.

Pixel: 1 unit will be how much pixel

Millimeter: 1 unit will be how much millimeter

Auto Cal: Insert a standard micro-ruler into the microscope and adjust it to find the ruler image in PC screen. Click Auto calto be “√” and click Cal length. Choose one point on a line in the image----Draw a vertical line of another line through the chosen point. A window of calibration setting will jump out. Choose a position in the Name----Input the calibration name and input the standard distance between the two chosen lines in Millimeter----Click Save----OK. The auto calibration has been finished.

Etamcap

P.15

Measure:

Etamcap

Count: Count the number of something in image.

Itamcap Review

Length: Measure the distance directly between two chosen points after choosing the right parameter.